Brain Stethoscope Study Manuscript: Rapid Evaluation Of Seizures In the ICU

The Ceribell EEG System offers rapid EEG acquisition and conversion of EEG signals to sound (sonification) using a proprietary algorithm Ceribell EEG System (1) reliably provided rapid emergent EEG data, (2) accurately identified subclinicial seizures, (3) resulted in fewer non-seizing patients being treated, and (4) was easy to use by clinicians not trained to place […]

Brain Stethoscope Study Manuscript: Detecting Silent Seizures By Their Sound

Individuals without any prior EEG training can accurately determine whether the EEG represents seizures or nonseizure conditions Individuals without EEG training can detect ongoing seizures or seizure-like rhythmic periodic patterns by listening to sonified EEG Nonexperts listening to single-channel sonified EEGs detected seizures with remarkable sensitivity (students, 98%±5%; nurses, 95%±14%) compared to experts or nonexperts […]

Circumferential Montage Manuscript: Diagnostic Utility of 8-channel EEG For Detecting Generalized Seizure

The Ceribell circumferential montage EEG can be used in emergency situations to detect gross abnormalities Full and reduced EEG demonstrated similar accuracy when read by neurologists (fm-EEG: 95%, rm-EEG: 95%, p = 0.29) Resident physicians judged with similar accuracy (fm-EEG: 80%, rm-EEG: 80%, p = 0.05), Medical student accuracy was comparable (fm-EEG: 60%, rm-EEG: 57%, p = 0.68)

DECIDE Study Editorial: Sonification of Seizures: Music to Our Ears

Assessing performance of Ceribell Rapid Response EEG for Critical Care - Editorial

The study makes a significant contribution to the ongoing efforts to improve access to real-time EEG acquisition and reduce time to diagnosis The novel use of a simplified EEG montage paired with sonification system may be valuable in the acute assessment of patients with suspected NCSz, leading to more accurate diagnostic decision-making and increasing physicians’ […]

Circumferential Montage Manuscript: Diagnostic Value of Electroencephalography with Ten Electrodes in Critically Ill Patients

EEG recordings using a circumferential 10-electrode montage meet the gold standard for seizure detection Removing confounding factors, the overall concordance between fm-EEG and rm-EEG increased from 79.7% to 99.0%, and the sensitivity and specificity of rm-EEG compared to fm-EEG in detecting seizure cases increased to 97.5% and 100.0%, respectively. The concordance between fm-EEG and rm-EEG […]

Clarity AI Study Manuscript: Monitoring the Burden of Seizures in Critical Care with a Novel Machine Learning Method

Ceribell with Clarity provides 24/7 EEG monitoring with consistently high performance for seizure burden assessment and bedside alert Of the 179 EEG recordings in which Claritγ detected no seizures, [Clarity had a] negative predictive value of 99%. Individual expert raters displayed variability in both sensitivity (range 20–89%) and specificity (range 94–99%). The sensitivity for identifying […]

DECIDE Study Manuscript: Assessing The Impact of Ceribell Rapid Response EEG

Ceribell™ Rapid Response EEG was demonstrated to significantly improve clinical accuracy and confidence A substantial number of critically ill patients with altered mental status have nonconvulsive seizures; data suggests a clear association between prolonged nonconvulsive seizures and poor neurologic outcomes However, even in large academic medical centers with 24/7 in-house EEG technologists, access to conventional […]