Rapid EEG for Cardiac Arrest Patients Manuscript: Reduced EEG Montage Has A High Accuracy In the Post Cardiac Arrest Setting

Reduced EEG montage like that used by Ceribell Rapid EEG has a high accuracy for seizure triage in the post cardiac arrest setting A reduced electrode montage may be used for post cardiac arrest EEG monitoring Background patterns were almost perfectly assessed with a reduced montage Discharge patterns were identified with high accuracy
Circumferential Montage Manuscript: Limited-Montage EEG as a Tool for the Detection of Nonconvulsive Seizures

Limited-Montage EEG may be a valuable tool for the detection of nonconvulsive seizures Nonconvulsive seizures were detected with high accuracy using the limited electrode array configuration in hatband (circumferential Ceribell) montage. These findings suggest that in some patients with nonconvulsive seizures, limited-montage EEG may allow to identification of ictal and slow patterns.
Brain Stethoscope Study Manuscript: Rapid Evaluation Of Seizures In the ICU

The Ceribell EEG System offers rapid EEG acquisition and conversion of EEG signals to sound (sonification) using a proprietary algorithm Ceribell EEG System (1) reliably provided rapid emergent EEG data, (2) accurately identified subclinicial seizures, (3) resulted in fewer non-seizing patients being treated, and (4) was easy to use by clinicians not trained to place […]
Brain Stethoscope Study Manuscript: Detecting Silent Seizures By Their Sound

Individuals without any prior EEG training can accurately determine whether the EEG represents seizures or nonseizure conditions Individuals without EEG training can detect ongoing seizures or seizure-like rhythmic periodic patterns by listening to sonified EEG Nonexperts listening to single-channel sonified EEGs detected seizures with remarkable sensitivity (students, 98%±5%; nurses, 95%±14%) compared to experts or nonexperts […]
Circumferential Montage Manuscript: Diagnostic Utility of 8-channel EEG For Detecting Generalized Seizure

The Ceribell circumferential montage EEG can be used in emergency situations to detect gross abnormalities Full and reduced EEG demonstrated similar accuracy when read by neurologists (fm-EEG: 95%, rm-EEG: 95%, p = 0.29) Resident physicians judged with similar accuracy (fm-EEG: 80%, rm-EEG: 80%, p = 0.05), Medical student accuracy was comparable (fm-EEG: 60%, rm-EEG: 57%, p = 0.68)
Circumferential Montage Manuscript: Midline and Parasagittal Seizures Are Rare In Adult Patients

Combining data from 16 studies, the prevalence of midline or parasagittal abnormalities was 0.71% (1,211 of 169,510) The study clearly confirms that focal midline or parasagittal seizure are rare. In a cohort of 300 patients, 17 were found to have seizure activity; of these, only two were documented to have focal midline or parasagittal seizures […]
DECIDE Study Editorial: Sonification of Seizures: Music to Our Ears

The study makes a significant contribution to the ongoing efforts to improve access to real-time EEG acquisition and reduce time to diagnosis The novel use of a simplified EEG montage paired with sonification system may be valuable in the acute assessment of patients with suspected NCSz, leading to more accurate diagnostic decision-making and increasing physicians’ […]
Ceribell Signal Quality Manuscript: Signals Recorded With Rapid Response EEG And Conventional EEG Systems

Ceribell electrode signal quality was equivalent to conventional EEG The tested rapid response EEG system provides EEG data that is equivalent in quality to the recordings made using conventional EEG systems despite the fact that the rapid response system can be applied within a few minutes and with no reliance on specialized technologists Simultaneous recordings […]
Rapid EEG in Tertiary Care Manuscript: Utility of Rapid EEG – Experience From a Tertiary Care Medical Center

Assessing the utility of continuous and spot EEG in a tertiary care center by quantifying access time and diagnostic yield Even in a modern United States tertiary care setting with state-of-the-art EEG practice and 24 h on-call EEG technician services, there is a noticeable delay in access to EEG EEG access time was 3.7 ± […]
Rapid EEG in Community Hospital Manuscript: Rapid Response EEG For Urgent Evaluation of Patients In A Community ICU

This report confirms the ease of use and speed of acquisition and interpretation of Rapid EEG information Conventional EEG was significantly delayed (11.2 ± 3.6 hours) compared with RR-EEG (5.0 ± 2.4 minutes; P < .005) Use of RR-EEG helped clinicians rule out status epilepticus and prevent overtreatment in 4 of 10 cases [40%] RR-EEG […]
Circumferential Montage Manuscript: Diagnostic Value of Electroencephalography with Ten Electrodes in Critically Ill Patients

EEG recordings using a circumferential 10-electrode montage meet the gold standard for seizure detection Removing confounding factors, the overall concordance between fm-EEG and rm-EEG increased from 79.7% to 99.0%, and the sensitivity and specificity of rm-EEG compared to fm-EEG in detecting seizure cases increased to 97.5% and 100.0%, respectively. The concordance between fm-EEG and rm-EEG […]
Clarity AI Study Manuscript: Monitoring the Burden of Seizures in Critical Care with a Novel Machine Learning Method

Ceribell with Clarity provides 24/7 EEG monitoring with consistently high performance for seizure burden assessment and bedside alert Of the 179 EEG recordings in which Claritγ detected no seizures, [Clarity had a] negative predictive value of 99%. Individual expert raters displayed variability in both sensitivity (range 20–89%) and specificity (range 94–99%). The sensitivity for identifying […]